Complete UV PP-I Disinfection System - New Generation
Natural and automatic purification system.
Includes ballast, chamber, quartz, and UV bulb.
The Ballast is smaller and has an indicator on the transformer Replaces the old UV-3 regular generation The kit can be used in a spa that initially does not have a
UV disinfection system.
However, you will need to create a
By-Pass on your filtration circuit and connect it to this system.
The electrical connection of the Ballast (transformer) is made via an AMP plug, so it will be suitable for most spa control systems.
Chamber Dimensions:- Length without ballast: 345mm
- Length with ballast: 420mm
- Diameter: 64mm
- Ends for 3/4 inch hoses
1" Fitting not included in this kit Average lifespan of a UV bulb: 9000 hours (approximately 1-2 years depending on usage)
Quartz tube lifespan: 2-3 years
Composition of the PP-I Wonder system: 
- Part No. 1: PG135 Ballast sealing ring
- Part No. 2: A02 Aluminum union ring between ballast and chamber
- Part No. 3: 4P80 4-pin connection plug to the bulb
- Part No. 4: T515 UV 15W bulb
- Part No. 5: 21735 Sealing gasket
- Part No. 6: t245350 Quartz tube
- Part No. 7: ST635345 UV disinfection chamber
- Part No. 8: 1002 Fixation clip
- Part No. 7: UV-22-anti-water-cover New generation ballast
| Model | Flow Rate (l/min) | Quartz Dimensions | Inlet and Outlet | Bulb Model | Ballast |
| PP-I UV-22 | 22.6 | Diameter 24.5mm / Length: 350mm | 1" | T515 | UV-22 220-240V |
| PP-II | 45.2 | Diameter 24.5mm / Length: 680mm | 1" | T529 | UV-6 |
| PP-III | 90.4 | Diameter 24.5mm / Length: 910mm | 1.5" | T540 | UV-6 |
 | UV Lamp: This is how ozone is produced in the upper atmosphere through sunlight rays |
Compatible with
Wonder brand UV lamp Ozonators
Commonly used in spas from Wellis® brand